[Abstract+References] Toward wearable supernumerary robotic fingers to compensate missing grasping abilities in hemiparetic upper limb 

This paper presents the design, analysis, fabrication, experimental characterization, and evaluation of two prototypes of robotic extra fingers that can be used as grasp compensatory devices for a hemiparetic upper limb. The devices are the results of experimental sessions with chronic stroke patients and consultations with clinical experts. Both devices share a common principle of work, which consists in opposing the device to the paretic hand or wrist so to restrain the motion of an object. They can be used by chronic stroke patients to compensate for grasping in several activities of daily living (ADLs) with a particular focus on bimanual tasks. The robotic extra fingers are designed to be extremely portable and wearable. They can be wrapped as bracelets when not being used, to further reduce the encumbrance. Both devices are intrinsically compliant and driven by a single actuator through a tendon system. The motion of the robotic devices can be controlled using an electromyography-based interface embedded in a cap. The interface allows the user to control the device motion by contracting the frontalis muscle. The performance characteristics of the devices have been measured experimentally and the shape adaptability has been confirmed by grasping various objects with different shapes. We tested the devices through qualitative experiments based on ADLs involving five chronic stroke patients. The prototypes successfully enabled the patients to complete various bimanual tasks. Results show that the proposed robotic devices improve the autonomy of patients in ADLs and allow them to complete tasks that were previously impossible to perform.

Alley R, Williams TI, Albuquerque M, . (2011) Prosthetic sockets stabilized by alternating areas of tissue compression and release. Journal of Rehabilitation Research and Development 48(6): 679. Google Scholar CrossRef, Medline
ArbotiX© (2012) ArbotiX-M Robocontroller. Available at: http://www.trossenrobotics.com/p/arbotix-robot-controller.aspx. (accessed 20 May 2017)
Aszmann OC, Roche AD, Salminger S, . (2015) Bionic reconstruction to restore hand function after brachial plexus injury: A case series of three patients. Lancet 385(9983): 21832189. Google Scholar CrossRef, Medline
Balasubramanian S, Klein J, Burdet E (2010) Robot-assisted rehabilitation of hand function. Current Opinion in Neurology 23(6): 661670. Google Scholar CrossRef, Medline
Belter JT, Segil JL (2013) Mechanical design and performance specifications of anthropomorphic prosthetic hands: A review. Journal of Rehabilitation Research and Development 50(5): 599. Google Scholar CrossRef, Medline
Bicchi A, Bavaro M, Boccadamo G, . (2008) Physical human–robot interaction: Dependability, safety, and performance. In: 10th IEEE international workshop on advanced motion control, Trento, Italy, 26–28 March 2008, pp. 914. Piscataway, NJ: IEEE. Google Scholar CrossRef
Birglen L, Lalibertè T, Gosselin C (2008) Underactuated Robotic Hands. Berlin: Springer. Google Scholar CrossRef
Brott T, Adams H, Olinger CP, . (1989) Measurements of acute cerebral infarction: A clinical examination scale. Stroke 20(7): 864870. Google Scholar CrossRef, Medline
Çalli B, Walsman A, Singh A, . (2015) Benchmarking in manipulation research: The YCB object and model set and benchmarking protocols. arXiv abs/1502.03143. Google Scholar
Casson AJ, Logesparan L, Rodriguez-Villegas E (2010) An introduction to future truly wearable medical devices—from application to ASIC. In: 2010 annual international conference of the IEEE Engineering in Medicine and Biology Society, Buenos Aires, Argentina, 31 August–4 September 2010, pp. 34303431. Piscataway, NJ: IEEE. Google Scholar CrossRef
Catalano MG, Grioli G, Farnioli E, . (2014) Adaptive synergies for the design and control of the Pisa/IIT SoftHand. International Journal of Robotics Research 33(5): 768782. Google Scholar Link
Davis WE, Burton AW (1991) Ecological task analysis: Translating movement behavior theory into practice. Adapted Physical Activity Quarterly 8(2): 154177. Google Scholar CrossRef
Demers L, Weiss-Lambrou R, Ska B (2002) The Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST 2.0): An overview and recent progress. Technology and Disability 14(3): 101105. Google Scholar
Dollar AM, Howe RD (2010) The highly adaptive SDM hand: Design and performance evaluation. International Journal of Robotics Research 29(5): 585597. Google Scholar Link
Dollar AM, Howe RD (2011) Joint coupling design of underactuated hands for unstructured environments. International Journal of Robotics Research 30(9): 11571169. Google Scholar Link
Eppner C, Brock O (2013) Grasping unknown objects by exploiting shape adaptability and environmental constraints. In: 2013 IEEE/RSJ international conference on intelligent robots and systems, Tokyo, Japan, 3–7 November 2013, pp. 40004006. Piscataway, NJ: IEEE. Google Scholar CrossRef
Falco J, Van Wyk K, Liu S, . (2015) Grasping the performance: Facilitating replicable performance measures via benchmarking and standardized methodologies. IEEE Robotics & Automation Magazine 22(4): 125136. Google Scholar CrossRef
Farina D, Merletti R (2000) Comparison of algorithms for estimation of EMG variables during voluntary isometric contractions. Journal of Electromyography and Kinesiology 10(5): 337349. Google Scholar CrossRef, Medline
Felzer T, Freisleben B (2002) HaWCoS: the hands-free wheelchair control system. In: Proceedings of the fifth international ACM conference on assistive technologies, Edinburgh, Scotland, 8–10 July 2002, pp. 127134. New York: ACM. Google Scholar CrossRef
Gafford J, Ding Y, Harris A, . (2014) Shape deposition manufacturing of a soft, atraumatic, deployable surgical grasper. Journal of Medical Devices 8(3): 030927. Google Scholar CrossRef
Gillen G (2015) Stroke Rehabilitation: A Function-Based Approach. St. Louis, MO: Elsevier Health Sciences. Google Scholar
Go AS, Mozaffarian D, Roger VL, . (2014) Heart disease and stroke statistics—2014 update: A report from the American Heart Association. Circulation 129(3): e28. Google Scholar CrossRef, Medline
Graf C (2008) The Lawton instrumental activities of daily living scale. American Journal of Nursing 108(4): 5262. Google Scholar CrossRef, Medline
Heo P, Gu GM, Lee SJ, . (2012) Current hand exoskeleton technologies for rehabilitation and assistive engineering. International Journal of Precision Engineering and Manufacturing 13(5): 807824. Google Scholar CrossRef
Holland DP, Park EJ, Polygerinos P, . (2014) The soft robotics toolkit: Shared resources for research and design. Soft Robotics 1(3): 224230. Google Scholar CrossRef
Hussain I, Meli L, Pacchierotti C, . (2015a) Vibrotactile haptic feedback for intuitive control of robotic extra fingers. In: Proceedings of the IEEE world haptics conference, Evanston, IL, 22–26 June 2015, 394399. Piscataway, NJ: IEEE. Google Scholar CrossRef
Hussain I, Salvietti G, Malvezzi M, . (2017a) On the role of stiffness design for fingertip trajectories of underactuated modular soft hands. In: Proceedings of the IEEE international conference on robotics and automation. Singapore, 29 May–3 June 2017. Piscataway, NJ: IEEE. Google Scholar CrossRef
Hussain I, Salvietti G, Meli L, . (2015b) Using the robotic sixth finger and vibrotactile feedback for grasp compensation in chronic stroke patients. In: Proceedings of the IEEE/RAS-EMBS international conference on rehabilitation robotics, Singapore, 11–14 August 2015, pp. 6772. Piscataway, NJ: IEEE. Google Scholar CrossRef
Hussain I, Salvietti G, Spagnoletti G, . (2016) The Soft-SixthFinger: A wearable EMG controlled robotic extra-finger for grasp compensation in chronic stroke patients. IEEE Robotics and Automation Letters 1(2): 10001006. Google Scholar CrossRef
Hussain I, Salvietti G, Spagnoletti G, . (2017b) A soft supernumerary robotic finger and mobile arm support for grasping compensation and hemiparetic upper limb rehabilitation. Robotics and Autonomous Systems 93: 112. Google Scholar CrossRef
Kiguchi K, Tanaka T, Fukuda T (2004) Neuro-fuzzy control of a robotic exoskeleton with EMG signals. IEEE Transactions on Fuzzy Systems 12(4): 481490. Google Scholar CrossRef
Konrad P (2005) The ABC of EMG: A Practical Introduction to Kinesiological Electromyography. Scottsdale, AZ: Noraxon, Inc. Google Scholar
Laschi C, Cianchetti M (2014) Soft robotics: New perspectives for robot bodyware and control. Frontiers in Bioengineering and Biotechnology 2: 3. Google Scholar CrossRef, Medline
Lum PS, Godfrey SB, Brokaw EB, . (2012) Robotic approaches for rehabilitation of hand function after stroke. American Journal of Physical Medicine & Rehabilitation 91(11): S242S254. Google Scholar CrossRef, Medline
Lund AM (2001) Measuring usability with the USE questionnaire. Usability Interface 8(2): 36. Google Scholar
Ma RR, Belter JT, Dollar AM (2015) Hybrid deposition manufacturing: Design strategies for multimaterial mechanisms via three-dimensional printing and material deposition. Journal of Mechanisms and Robotics 7(2): 021002. Google Scholar CrossRef
Meng Q, Lee MH (2006) Design issues for assistive robotics for the elderly. Advanced Engineering Informatics 20(2): 171186. Google Scholar CrossRef
Merletti R, Botter A, Troiano A, . (2009) Technology and instrumentation for detection and conditioning of the surface electromyographic signal: State of the art. Clinical Biomechanics 24(2): 122134. Google Scholar CrossRef, Medline
Merlo A, Campanini I (2010) Technical aspects of surface electromyography for clinicians. The Open Rehabilitation Journal 3(1): 98109. Google Scholar CrossRef
Michaelsen SM, Jacobs S, Roby-Brami A, . (2004) Compensation for distal impairments of grasping in adults with hemiparesis. Experimental Brain Research 157(2): 162173. Google Scholar CrossRef, Medline
Miguelez J, Miguelez M, Alley R (2004) Amputations about the shoulder: Prosthetic management. Atlas of Amputations and Limb Deficiencies—Surgical, Prosthetic, and Rehabilitation Principles. Rosemont, IL: American Academy of Orthopaedic Surgeons, 263273. Google Scholar
Nakayama H, Jorgensen HS, Raaschou HO, . (1994) Compensation in recovery of upper extremity function after stroke: The Copenhagen Stroke Study. Archives of Physical Medicine and Rehabilitation 75(8): 852857. Google Scholar CrossRef, Medline
Nowak DA (2008) The impact of stroke on the performance of grasping: Usefulness of kinetic and kinematic motion analysis. Neuroscience & Biobehavioral Reviews 32(8): 14391450. Google Scholar CrossRef, Medline
Odhner LU, Jentoft LP, Claffee MR, . (2014) A compliant, underactuated hand for robust manipulation. International Journal of Robotics Research 33(5): 736752. Google Scholar Link
Ort T, Wu F, Hensel NC, . (2015) Supernumerary robotic fingers as a therapeutic device for hemiparetic patients. In: ASME 2015 dynamic systems and control conference, Columbus, OH, 28–30 October 2015, p. V002T27A010. New York: American Society of Mechanical Engineers. Google Scholar CrossRef
Oskoei MA, Hu H (2007) Myoelectric control systems—a survey. Biomedical Signal Processing and Control 2(4): 275294. Google Scholar CrossRef
Pons J, Rocon E, Ceres R, . (2004) The MANUS-HAND dextrous robotics upper limb prosthesis: Mechanical and manipulation aspects. Autonomous Robots 16(2): 143163. Google Scholar CrossRef
Pons JL (2008) Wearable Robots: Biomechatronic Exoskeletons. Chichester: Wiley. Google Scholar CrossRef
Pons JL (2010) Rehabilitation exoskeletal robotics. IEEE Engineering in Medicine and Biology Magazine 29(3): 5763. Google Scholar CrossRef, Medline
Prattichizzo D, Malvezzi M, Hussain I, . (2014a) The Sixth-Finger: A modular extra-finger to enhance human hand capabilities. In: Proceedings of the IEEE international symposium in robot | human interactive communication. Edinburgh, UK, 25–29 August 2014. Piscataway, NJ: IEEE. Google Scholar CrossRef
Prattichizzo D, Salvietti G, Chinello F, . (2014b) An object-based mapping algorithm to control wearable robotic extra-fingers. In: Proceedings of the IEEE/ASME international conference on advanced intelligent mechatronics. Besanon, France, 8–11 July 2014. Piscataway, NJ: IEEE. Google Scholar CrossRef
Raghavan P, Krakauer JW, Gordon AM (2006) Impaired anticipatory control of fingertip forces in patients with a pure motor or sensorimotor lacunar syndrome. Brain 129(6): 14151425. Google Scholar CrossRef, Medline
Robotis© (2012) Dynamixel MX-28T robot actuator. Available at: http://www.trossenrobotics.com/dynamixel-mx-28-robot-actuator.aspx . (accessed 20 May 2017)
Salvietti G, Hussain I, Cioncoloni D, . (2016) Compensating hand function in chronic stroke patients through the robotic sixth finger. IEEE Transactions on Neural System and Rehabilitation Engineering 25(2): 142150. Google Scholar CrossRef, Medline
Saponas TS, Tan DS, Morris D, . (2008) Demonstrating the feasibility of using forearm electromyography for muscle–computer interfaces. In: Proceedings of the SIGCHI conference on human factors in computing systems, Florence, Italy, 5–10 April 2008, pp. 515524. New York: ACM. Google Scholar CrossRef
Schwarz RJ (1955) The anatomy and mechanics of the human hand. Artificial Limbs 2(2): 2235. Google Scholar Medline
Stanger CA, Anglin C, Harwin WS, . (1994) Devices for assisting manipulation: A summary of user task priorities. IEEE Transactions on Rehabilitation Engineering, 2(4): 256265. Google Scholar CrossRef
Timoshenko S, Gere J (1972) Mechanics of Materials. New York: Van Nostrand Reinhold Co. Google Scholar
Vanderborght B, Albu-Schäffer A, Bicchi A, . (2013) Variable impedance actuators: A review. Robotics and Autonomous Systems 61(12): 16011614. Google Scholar CrossRef
Van der Loos HM, Reinkensmeyer DJ (2008) Rehabilitation and health care robotics. In: Siciliano B, Khatib O (eds.) Springer Handbook of Robotics. Berlin: Springer, pp. 12231251. Google Scholar CrossRef
Webb J, Xiao ZG, Aschenbrenner KP, . (2012) Towards a portable assistive arm exoskeleton for stroke patient rehabilitation controlled through a brain computer interface. In: 4th IEEE RAS & EMBS international conference on biomedical robotics and biomechatronics, Rome, Italy, 24–27 June 2012 pp. 12991304. Piscataway, NJ: IEEE. Google Scholar CrossRef
Wu F, Asada H (2014) Bio-artificial synergies for grasp posture control of supernumerary robotic fingers. In: Robotics: science and systems, Berkeley, CA, 12–16 July 2014. Cambridge, MA: MIT Press Google Scholar CrossRef
Wu FY, Asada HH (2016) Implicit and intuitive grasp posture control for wearable robotic fingers: A data-driven method using partial least squares. IEEE Transactions on Robotics 32(1): 176186. Google Scholar CrossRef
Zecca M, Micera S, Carrozza M, . (2002) Control of multifunctional prosthetic hands by processing the electromyographic signal. Critical Reviews in Biomedical Engineering 30(4–6): 459485. Google Scholar CrossRef, Medline

Source: Toward wearable supernumerary robotic fingers to compensate missing grasping abilities in hemiparetic upper limbThe International Journal of Robotics Research – Irfan Hussain, Giovanni Spagnoletti, Gionata Salvietti, Domenico Prattichizzo, 2017

Advertisements

, , , , , , ,

  1. Leave a comment

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

%d bloggers like this: